Aim:
NPWT has been advocated for virtually all kinds of acute and chronic wounds. Treatment is based on local negative pressure applied to the wound surface. NPWT is mainly carried out using open-cell polyurethane foams. It could be shown that cells show a significant tendency to grow into these foams which can be inhibited by application of drainage foil** without interfering with induction of cell migration. It is of interest to investigate if this combination is robust and workable with different vacuum pumps***.
Method:
Drainage foil** was placed on fibroblast 3D-cultures in combination with largepored PU foam*. Assemblies were positioned in Petri dishes and sealed with air-tight film after medium supply and vacuum pumps*** were connected. Experiments were carried out at -80mmHg and -120 mmHg for 48h. Cell viability and ingrowths of cells into samples was
determined.
Results / Discussion:
Combination of drainage foil** and PU foam* samples during NPWT with different vacuum pumps*** led to the same cellular responses in vitro. With the PU foam* alone, cells did not stop at the pellicle edge but continued to migrate into the
dressing. In contrast, placement of drainage foil** between collagen pellicle and PU foam* inhibited ingrowths of cells into the foam.
Conclusion:
It was shown that combination of drainage foil** with PU foam* for NPWT is workable with pumps from different manufacturers***. Ingrowths of cells into large-pored foams can be inhibited in vitro by application of drainage foil**. In vivo this may prevent disruption of newly formed tissue during dressing changes.
Aim:
A polyacrylate containing super absorbent dressing* can be used for patients with moderate-to-high exuding wounds. The study evaluated the performance of the superabsorbent dressing* in daily clinical practice.
Method:
German physicians from different specialisms participated: 23 general medicine, 13 surgery, 14 internal medicine and 3 other departments. Both the dressing and questionnaire were supplied by the sponsor. After dressing use the physicians scored on handling properties, absorbent capacity, user satisfaction and patient comfort. The super absorbent dressing* was used for at least 3 dressing changes in 171 patients (86 (50.3%) men, 78 (45.6%) women, 7 (4.1%) not scored).
Results / Discussion:
The centers used their current protocol. The patients had pressure ulcers (8 (4.7%), venous leg ulcers (113 (66%), diabetic foot ulcers (8 (4.7%), post-surgery (14 (8.2) and infected wounds (8 (4.7%). Dressing application was rated easy by 168 (95%) of the clinicians and the dressing demonstrated a good absorbent capacity as noted by 167 (98%) of the respondents. The dressing was rated easy to remove (168 (98.3%) and did not soil clothing according to 165 (97%) of the respondents. N=157 (94%) patients reported to be satisfied with the performance of the dressing as well as 166 (99%) of the physicians, who additionally reported (156 (94.6%) the dressing to be safe and reliable for the task at hand.
Conclusion:
The study design allowed for collecting data on the dressing in daily clinical practice. The evaluated dressing* was easy to use, comfortable and reliable for patients with moderate-to-high exuding wounds.
Aim:
Compression remains the gold standard for long-term management of chronic edema. Reviews have shown that the benefits of compression diminish according to levels of non-adherence. Reasons commonly stated for nonadherence to compression include inconvenience, heat, cost, and pain. We hypothesize that offering compression options will have positive impact on patients’ compliance and concordance to compression regimens.
Method:
Observational study performed at 2 different edema management clinics. Ten patients presenting with lower extremity swelling and history of non-compliance with previous compression regiments were observed. Objective data measured included limb volume, range of motion (ROM), functional activity status using the Timed Up and Go(TUG), and assessment of quality of life (QOL) using the Lymphoedema QOL Tool (LYMQOL-LEG). Measurements were taken at four different intervals over a minimum of 3 months. Compression options were individualized to patient's physical presentation and lifestyle for long term management of their edema.
Results / Discussion:
Compression therapy had a positive impact on all outcomes measured during the intensive phase of therapy. Follow-up outside the intensive phase of therapy demonstrated further volume loss in 6/10 subjects; Volume remained constant 3/10, increased slightly 1/10. LYMQOL scores and functional performance level maintained stable during the follow-up period.
Conclusion:
Offering multiple compression options including custom and ready-to-wear flat knit stockings*, an adjustable wrap ** and nighttime compression options*** had a positive impact on patients’ adherence to compression regimens during the study period compared to single compression modalities offered previously. Individualizing the compression regimen to each patient’s lifestyle improved their adherence to chronic edema management.
Aim:
To review the evidence supporting the use of Monofilament fibre debridement technology (MFDT) in dermatological conditions.
Method:
MFDT has been successfully used for 7 years in the debridement and management of chronic wounds¹ and hyperkeratosis². In recent years clinicians have been utilizing the MFT in specific dermatological skin conditions.
Results / Discussion:
MFDT has been shown in case studies and case series to be a useful emerging treatment, especially when self-care is a priority, in the management of dermatological conditions resulting in:
Varicose eczema
Epidermolysis bullosa
Chronic wounds in dermatological patients
Dry, scaly and flaky skin conditions
Hyperkeratosis associated with venous disease
Secondary skin changes associated with chronic oedema and lymphoedema
Actinic keratosis
Prior to photodynamic therapy
Acne vulgaris
The 18 million special monofilament fibres which have angled tips to reach uneven areas of the skin or wound bed are able to remove unwanted tissue, materials and skin, allowing other concurrent treatment to reach their target area without the barriers imposed by for e.g. devitilised tissue, dry, scaly and flaky skin and other debris and materials. This technology has received positive NICE guidance¹⁷ for use in acute and chronic wounds. MFDT is very soft, comfortable and gentle on patients. It is safe and easy to use and can also be used by patients for self-care.
Conclusion:
A review of the supporting evidence clearly supports the continued research and interest in MFDT related to dermatological conditions.
Aim:
To evaluate the performance of Monofilament Fibre Debridement Technology compared to a cleaning cloth in the removal of bacteria and biofilm using a wound intelligence device which leverages the principles of fluorescence.
Method:
Patients were selected with chronic wounds who demonstrated signs that biofilm was the primary cause of the wound being static or slow to heal. A monofilament fibre debridement pad was used to mechanically debride the chronic wounds and expedite wound bed preparation. The same procedure was repeated using a cleaning cloth with poloxamer following manufacturer’s instructions for use. A wound intelligence device was used to take images of fluoresce in bacteria ≥ 10⁴ CFU/g on the surface of the wound bed before and after using the monofilament fibre debridement pad and compared with the before and after images using the cleaning cloth.
Results / Discussion:
To date, eight patients have been recruited into the evaluation, four using the monofilament fibre debridement pad and four using the cleaning cloth. In all cases, images demonstrate that the monofilament fibre debridement technology has superior ability to removal bacteria and biofilm when compared to the cleaning cloth with poloxamer. Data collection continues.
Conclusion:
To date, the monofilament fibre debridement technology has shown better removal of bacteria and biofilm when compared with a cleaning cloth using fluoresce imaging in the evaluation.
Aim:
The study compared clinical efficacy and cost of autolitic, enzymatic and mechanical debridement using a monofillament pad* and a pad with a handle.
Method:
A monofilament debrider was proposed for its efficacy, safety, tolerability and ease of use. Eighty community patients with complex wounds containing sloughy tissue were allocated to the treatment groups at random, after they consented. They were followed for 15 days. At baseline medical history, wound characteristics and privious treatment was recorded. During visits wound condition, patient reported pain during debridement, time required for the procedure and product handling, were scored. Costs calculation took into account clinical efficacy, time to debridement, number of home visits, nursing costs, costs
per product used.
Results / Discussion:
Debridement was effective and comfortable using all evaluated methods (on a 5-point Likert scale, the 2 monofilament products scored a mean of 4,9 and 4,8, enzymatic sored a mean of 4,6 and autolytic debridement a mean of 3,6). The total costs for debridement using the monofilament pad* and product with handle was Euro 58,67 and Euro 72,47 respectively. For enzymatic debridement the total costs were Euro 213,35 and for autolytic debridement Euro 98,67. Cost was significantly lower in the monofilament group due to a reduction in debridement time, number of visits and nursing time.
Conclusion:
The addition of the monofilament products to our debridement portfolio use for wound management in the community represents an added value in the treatment available for patients with complex wounds with appropriate use of tight resources.
Aim:
Although hosiery is the golden standard in the maintenance phase for treating lymphedema or venous leg ulcers, clinical challenges exist where hosiery may not be suitable due to unresolved edema or practical application issues. In this study a practical solution for this group of patients was implemented using a Leg Ulcer Hosiery Treatment System.*
Method:
9 patients, 5 males, 4 females aged between 45 – 87 years old. 7/9 edema, I erysipelas and I DVT. Previous treatment: 6/7 no treatment, 2 Tubigrip, 1 ill-fitting hosiery Referrals from the General Practitioner or Medical Specialists to the bandager Medical Stockings measurement. In all cases edema persisted and an alternative solutions was chosen using the new system for 4 – 6 weeks for treatment of the edema.
Results / Discussion:
After evaluation, there was an immediate effect reduction in edema, from 6 to 14%. Comfort and Donning was good to very good. Doffing was average to good. Patients were able to wear their own shoes, stay active and in some cases, continue working. They were measured for follow on Medical Stockings. The system was simple, effective, promoted self-care and was available off the shelf. Costs of bandager and community nurse time were reduced.
Conclusion:
Simple solutions such as the 2 layer Leg Ulcer System can help patients and caregivers for the treatment of edema with or without a wound. Benefits are self-management and cost efficiency instead of 2 – 3 x week bandaging. All patients could fit into their own shoes, and this motivates mobility.
Aim:
Complex case management in a fragile elderly patient to achieve an optimal outcome.
Method:
The 96 year-old female had a deep wound infection after osteosynthesis of her left ankle. In the hospital she was treated with negative pressure wound therapy (NPWT). Upon arrival on March 2, 2017 in the rehabilitation centre the wound surface was 8 x 3 cm, the wound bed contained 10% yellow and 90% granulation tissue with some hyper-granulation present. The wound edges were non vital and there was oedema in her left ankle. The surrounding skin was slightly red.
Results:
The patient received nutritional supplements twice daily. NPWT was discontinued and the treatment regime now comprised: Debridement using a monofilament1 pad, followed by cleansing with water and disinfection with an antiseptic. The peri-wound skin was protected with a spray on film, a collagen2 and an alginate3 dressing were covered with a superabsorbent pad fixed with an adhesive film dressing.4 Dressing changes were on average twice weekly. For compression 2 layers (20 mmHg) of a tubular compression5 system were applied during the day and reduced to one layer at night. Wound closure was achieved after 41 days of treatment. The patient continued with the compression system for another 6 weeks to protect the fragile area and to prevent oedema from reoccurring.
Conclusion:
Complex wound closure was achieved in a comfortable fashion that suited the individual needs of this elderly fragile patient.
Aims
To evaluate the performance of a gel forming wound contact layer* in static or slow-to-heal chronic wounds following wound bed preparation using monofilament fibre debridement technology**.
Methods
Eleven patients (9 females, 2 males) were selected with low to moderately exuding wounds – 10 of which were leg ulcers. The mean age was 71 years. All patients underwent wound bed preparation using monofilament fibre debridement technology at dressing changes followed by application of a gel forming wound contact layer. The patients were followed up weekly or twice weekly for five dressing changes or until healed. Both quantitative and qualitative parameters were measured at each dressing change.
Results/Discussion
In all cases, the chronic wounds went on to show positive signs of healing, with many reducing greatly in size or healing.
The gel forming wound contact layer resulted in 100% reduction in pain scores during treatment, 100% rated very good application and removal (non-adherent) and 100% rated very good or good improvement of the condition of peri-wound skin.
Results demonstrated very high patient and clinician satisfaction scores with 90% receiving 8 – 10 out of 10.
Conclusion
The gel forming wound contact layer proved easy to use, safe, effective and highly recommended by patients and clinician.
Aim:
Non-healing wounds contain elevated levels of neutrophil elastase and matrix metalloproteinases (MMPs) which are responsible for degradation of extracellular matrix and growth factors. These destructive processes prevent wound closure and lead to persisting wounds. Binding of these proteases contributes to the treatment of chronic wounds. The aim of this study was to compare the binding capacity of two polyacrylatesuperabsorber dressings* for elastase and MMP-2 in vitro.
Method:
Samples of SAP* and SAP Pro** were cut (0.5 cm2), taken in a final volume of 1mL of protease solution (PMN elastase: 250ng/mL; MMP-2: 4000pg/mL), and incubated up to 24h at 37°C. Concentrations of unbound protein were determined by specific immunoassays for PMN elastase and MMP-2. In addition, it was checked if proteases can be eluted from the dressing samples subsequently.
Results / Discussion:
SAP* exhibited high binding capacity for both proteases. After 24h elastase concentrations were significantly reduced about 95% (p<0.001) and MMP-2 amounts completely abolished (100%, p<0.001). Only marginal amounts of elastase andMMP-2 could be eluted from the samples after incubation. SAP Pro** demonstrated a comparable high binding of elastase and MMP-2. No distinct differences in the performance of the dressings were noted.
Conclusion:
The polyacrylate superabsorber dressings SAP* and SAP Pro** are able to shortly bind large amounts of elastase and MMP-2 in vitro. Elution of the dressing samples revealed a strong, possibly irreversible binding of both proteases. Decrease of these matrix degrading proteases should aid establishment of a physiological wound milieu in vivo and thus support the healing process.